ICT cooling applications

Cooling Fans for Information and Communications Technology

AC and DC axial fan applications for network switches, telecom cabinets, edge computing hardware, communication power supplies and auxiliary rack ventilation.

Information and Communications TechnologyA server rack, network router and radio tower represent information and communications technology.
Servers, networks & telecommunications

From compact communication modules to larger equipment enclosures, the cooling task is to move air through the real flow path—not simply achieve a free-air rating.

Server rack ventilation conceptA rack contains three computing units. Teal arrows show the concept of intake airflow through equipment toward an exhaust path.IntakeExhaust
Conceptual equipment and airflow illustration.

Server & Data Center Equipment

Auxiliary ventilation for rack enclosures, server-side airflow paths and control electronics. Check flow direction and pressure at the installed operating point.

Edge gateway and network switch cooling conceptA compact enclosure contains processor and power electronics, with a local cooling fan and a directed airflow path.Electronics · heat sink · local airflow
Conceptual equipment and airflow illustration.

Edge Computing & Network Devices

Localized airflow for processors, power modules, gateways and optical equipment. Verify fan thickness, inlet clearance and acoustic requirements.

Protected telecom cabinet ventilation conceptA telecom enclosure has a protected inlet and exhaust grille. The illustration identifies the enclosure airflow path, not a fan weatherproof rating.Protected inletExhaust grille
Conceptual equipment and airflow illustration.

Telecom Cabinets & Power Systems

Enclosure ventilation for communications hardware and power-control electronics. Outdoor installations need an appropriate protection and filtration design.

The illustrations show typical cooling arrangements, not specific customer installations or exact fan mounting designs. Confirm dimensions and equipment requirements for the selected model.

Fan models & ICT application table

Find a starting point for your equipment

These reference applications follow the supplied brief. Select a linked series to review its model-specific dimensions, supply options and performance data.

Reference applications for engineering review; not a verified fit or performance guarantee for every installation.
Fan ModelTypical ICT Application
AC8025Small network switches, communication power modules
AC8038Edge gateway cabinets, compact telecom control boxes
AC9225Mini routers, optical transmission equipment
AC9238Indoor small base station cabinets, telecom power supplies
AC110251U/2U server auxiliary cooling, network chassis
AC12025Server rack side ventilation, network switch cabinets
AC12038Telecom battery cabinets, data center control cabinets
AC17238Medium-size base station cabinets, edge AI computing enclosures
AC17251Outdoor telecom cabinets, high-airflow network equipment
AC17255Large edge computing enclosures, telecom power cabinets
AC20572Large server rack ventilation, telecom equipment enclosures
AC18060Medium data center auxiliary ventilation
AC20060High-power telecom cabinets, rack-mounted computing units
AC22580Large telecom base station cabinets
AC25489Data center rack exhaust, heavy-duty telecom enclosures
AC28080Large-scale data center auxiliary ventilation systems
AC15050Compact optical communication modules, small network devices
DC2006 / DC2010Mini optical transceivers, small network sensors
DC2507 / DC2510Mini network adapters, compact communication modules
DC3007 / DC3010Small gateways, 5G communication micro-modules
DC4007 / DC4010 / DC4015 / DC4020 / DC4028Mini routers, optical communication equipment, edge microcontrollers

AC and DC model labels follow the supplied brief. Linked product pages use the corresponding JyFan JA and JF series names. For AC12025, review both listed configurations on the linked page.

Match the fan to the enclosure, not just the device label. A larger fan reference may concern the equipment housing or auxiliary ventilation rather than a fan fitted directly inside a compact module. Confirm rack-unit height, mounting space, airflow path and electrical compatibility.

Selection considerations

Specify the operating conditions that matter

Airflow at system pressure

Filters, grilles, heat sinks and cable routing add resistance. Define the required airflow and pressure, then check the fan curve at that operating point.

Read the PQ curve guide →

Mechanical & electrical integration

Confirm the mounting drawing, enclosure clearances, supply voltage, frequency where relevant, starting requirements and cable or connector arrangement.

Control, monitoring & acoustics

Check available PWM, speed feedback or alarm options for the exact variant. Evaluate installed noise and the equipment’s maintenance and redundancy strategy.

Environmental protection

Review ambient temperature, dust, humidity, condensation and corrosion. An outdoor cabinet application does not imply that a standard fan is rated for direct weather exposure; confirm the complete enclosure protection concept.

AC and DC axial fans can support heat dissipation across ICT equipment from compact electronics to larger rack systems. The required airflow, effective pressure and suitable model depend on the full installation.

Plan cooling for your ICT equipment.

Send your voltage, airflow, pressure, mounting requirements and operating environment.

Request a Quote →