Slim-type AC axial fan, suitable for limited mounting depth.
Industry
Typical equipment & applications
1. Industrial Control & Power Supply Industry
Medium‑high power switching power supplies, industrial inverters; frequency converters, servo control systems; internal cooling & ventilation for electrical control cabinets and PLC enclosures; heat dissipation for compact energy‑storage power modules.
2. Instruments & Industrial Testing Equipment
Benchtop high‑power testing instruments; laboratory burn‑in test equipment; welding electrical control cabinets; ventilation & cooling for test‑analysis devices.
3. Industrial & Laser Equipment
Electric control cabinets for medium‑and‑small laser machines; control cabinets for automation equipment; enclosure cooling for 3D‑printing machines.
4. Medical Device Industry
Internal heat dissipation for medium‑power physical‑therapy equipment and medical analytical instruments. (Note: Dual ball‑bearing version is recommended for long‑term continuous operation)
5. Commercial Self‑Service Equipment
Vending machines, self‑service kiosks; heat dissipation for high‑power advertising player enclosures and stage‑lighting equipment.
6. Telecommunications Industry
Internal cooling & ventilation for medium‑and‑small‑sized telecommunication cabinets, industrial switches and network transmission equipment enclosures.
High‑power air purifiers, dehumidifiers, space heaters; ventilation cooling for selected commercial temperature‑control devices.
Published model data from the corresponding JyFan source specification. Paired performance values follow the frequency order shown in the source sheet.
Model
Voltage (V)
Current (A)
Power (W)
RPM
Airflow (CFM)
Static Pressure (mmH₂O)
Noise (dBA)
Bearing
Life
Weight (g)
JA11025HB1
110-120
0.16/0.14
15/12
2100/2300
48/56
4.0/4.3
34/37
Dual Ball
50,000 hrs continuous operation at 25°C, 65% RH
280
JA11025HS1
110-120
0.16/0.14
15/12
2100/2300
48/56
4.0/4.3
34/37
Sleeve
30,000 hrs continuous operation at 25°C, 65% RH
280
JA11025HB2
220-240
0.08/0.07
15/12
2100/2300
48/56
4.0/4.3
34/37
Dual Ball
50,000 hrs continuous operation at 25°C, 65% RH
280
JA11025HS2
220-240
0.08/0.07
15/12
2100/2300
48/56
4.0/4.3
34/37
Sleeve
30,000 hrs continuous operation at 25°C, 65% RH
280
Confirm the full model designation, frequency and test conditions before ordering. Validate performance at the finished equipment operating point.