Factory automation & edge computing

Industrial AI supports predictive maintenance, machine-vision inspection, process optimization, energy management, production scheduling and safety monitoring. The computing, control and power electronics behind these functions generate heat that must be managed within the equipment enclosure.

JyFan AC and DC axial fan families can be considered for thermal management in compact sensor modules, edge computing devices, industrial control cabinets and larger power enclosures. The appropriate fan depends on the heat load, enclosure airflow resistance, electrical supply and operating environment.

Reference series are starting points for an engineering review. Match the fan to the actual heat load, airflow resistance, electrical supply and operating environment.

12 industry scenarios

Where industrial AI needs cooling

01 / APPLICATION

Equipment Manufacturing

Typical applications
Intelligent machine tools, industrial robot control cabinets, automated production lines, and pump and valve monitoring systems.
Cooling task
Direct airflow across robot drive electronics, machine-tool edge AI hardware and predictive-maintenance gateways to help remove heat from enclosed components.
Reference fan series
Medium-size AC axial fans; DC4020 and DC4028 series.
Selection considerations
Match fan pressure capability to cabinet filters and airflow paths; consider vibration and continuous-duty requirements.
02 / APPLICATION

Automotive & Auto Parts

Typical applications
Electric vehicle assembly lines, battery production equipment and automated component inspection stations.
Cooling task
Ventilate AI vision-processing cabinets, battery-testing equipment and industrial controller power supplies.
Reference fan series
AC17238, AC20060 and DC40 series.
Selection considerations
Assess dust exposure, filter resistance and the thermal load of inspection processors and test electronics.
03 / APPLICATION

Electronics & Semiconductors

Typical applications
Smart SMT production lines, PCB automated optical inspection and semiconductor process-monitoring systems.
Cooling task
Provide localized airflow for compact AI sensor modules and process-control power units, or enclosure ventilation for machine-vision computers.
Reference fan series
DC2510, DC3010 and medium-size AC axial fans.
Selection considerations
Check installation space, particle-control requirements and the effect of vibration on sensitive equipment.
04 / APPLICATION

Iron & Non-Ferrous Metals

Typical applications
Smelting-line monitoring, rolling-mill control systems and automated material inspection stations.
Cooling task
Remove internally generated heat from industrial AI control cabinets and data-acquisition hardware where the surrounding air is suitable for cooling.
Reference fan series
AC22060 and AC25489.
Selection considerations
Check ambient temperature, dust loading and bearing life. Where inlet air is too hot or contaminated, evaluate a closed-loop cooling system.
05 / APPLICATION

Petrochemicals & Fine Chemicals

Typical applications
Refinery monitoring, chemical reactor control and predictive pipeline-corrosion monitoring.
Cooling task
Support airflow around AI processing units and power modules within an appropriately engineered enclosure cooling arrangement.
Reference fan series
AC20572 and AC28080, subject to application approval.
Selection considerations
Confirm chemical compatibility and the complete enclosure protection concept. Model references do not establish explosion-proof suitability or hazardous-area approval.
06 / APPLICATION

Power & Renewable Energy

Typical applications
Wind and solar monitoring, energy-storage stations, and intelligent high- and low-voltage distribution cabinets.
Cooling task
Ventilate battery management system electronics, inverter control enclosures and edge gateways. This application concerns electronics cooling rather than battery-cell cooling.
Reference fan series
AC18060, AC20572 and DC40 series.
Selection considerations
Check cabinet heat load, inlet temperature, service access and the need for fan-speed control or fault monitoring.
07 / APPLICATION

Mining

Typical applications
Mine-site monitoring, AI ore-sorting equipment and safety-monitoring cabinets.
Cooling task
Provide forced ventilation for industrial control enclosures and data-processing electronics in suitably protected installations.
Reference fan series
Large AC axial fan families; final model to be selected.
Selection considerations
Assess abrasion, dust, moisture and vibration. Underground or hazardous locations require application-specific equipment approval.
08 / APPLICATION

Pharmaceuticals & Medical Devices

Typical applications
Automated pharmaceutical production, medical-device inspection and cleanroom environmental monitoring.
Cooling task
Cool AI inspection instruments and compact control electronics where space and acoustic performance are important.
Reference fan series
Miniature and medium-size DC fan families; assess low-noise and ball-bearing options.
Selection considerations
Check particle-control needs, cleanability, noise and equipment compliance. Fan selection alone does not establish medical-device suitability.
09 / APPLICATION

Food & Beverage

Typical applications
Intelligent filling lines, visual food-inspection systems and cold-chain monitoring equipment.
Cooling task
Ventilate vision-processing enclosures and environmental controllers while maintaining the required separation from production and food-contact areas.
Reference fan series
DC30, DC40 and AC17251 series.
Selection considerations
Evaluate condensation, moisture ingress, washdown exposure and enclosure hygiene requirements.
10 / APPLICATION

Consumer Goods Manufacturing

Typical applications
Smart injection-molding workshops, automated textile inspection and appliance assembly lines.
Cooling task
Remove heat from shop-floor edge AI computers and industrial power-supply enclosures used for inspection and process control.
Reference fan series
AC17238 and DC40 series.
Selection considerations
Consider fibers, lint and dust, together with filter maintenance, mounting space and operating hours.
11 / APPLICATION

Ports & Intelligent Logistics

Typical applications
Automated container terminals, high-bay warehouses and conveyor-system monitoring.
Cooling task
Manage heat in AI control cabinets and signal-processing hardware supporting automated handling and warehouse operations.
Reference fan series
AC22580 and AC25489.
Selection considerations
Assess outdoor exposure, humidity, salt-laden air where applicable, and the resistance of protective filters and grilles.
12 / APPLICATION

Water Treatment & Environmental Monitoring

Typical applications
Intelligent wastewater control, continuous exhaust-gas monitoring and environmental data-acquisition stations.
Cooling task
Provide airflow for AI monitoring modules, data loggers and power-control enclosures.
Reference fan series
Miniature DC fans and medium-size AC axial fans; final model to be selected.
Selection considerations
Check humidity, condensation, corrosive atmospheres and enclosure ingress protection before selecting an open-air ventilation approach.

Selection & certification

Define the cooling requirement before selecting a model

Heat load & inlet temperature

Estimate component heat dissipation and the permitted temperature rise. Forced ventilation is suitable only when the available inlet air can provide useful cooling.

Airflow at operating pressure

Use the fan performance curve at the system operating point. Filters, grilles, ducts and densely packed components can substantially reduce delivered airflow.

Mechanical & electrical integration

Confirm dimensions, mounting, supply voltage and frequency where relevant, starting current, connector and cable routing. Check speed-control and alarm interfaces if required.

Environment & service life

Assess temperature, humidity, condensation, dust, vibration and corrosive exposure. Select the appropriate bearing arrangement and plan access for cleaning or replacement.

Noise & equipment requirements

Review acoustic targets and enclosure resonance. Verify any ingress-protection, hazardous-area, hygiene or equipment-specific requirements for the installation.

Reference fan series are based on the supplied brief. Confirm model specifications, suitability and applicable CE conformity or UL / TUV certification for the exact variant before use.

AC and DC reference labels follow the supplied application brief. Linked product pages use JyFan JA and JF model names for the corresponding series.

Plan cooling for your industrial AI equipment.

Share the heat load, supply voltage, airflow at pressure, mounting space and operating environment.

Request a Quote →

← All cooling applications