Skip to content
Home / DC fans / JF171

DC fans

JF171 — 171mm round DC cooling fan

Review the JF17151 aluminum round-frame DC axial fan, its mechanical dimensions, airflow curves and model-specific electrical performance.

Model selection

FamilyJF171
Model seriesJF17151
Frame / sizeØ171 × 51.5 mm (round) — JF17151
Power typeDC
FrameAluminum alloy (round)
ImpellerThermoplastic PBT, UL 94V-0
Bearing systemDual Ball
Life Expectancy50,000 hrs (Dual Ball) continuous operating under 25°C, 65% RH.
Rated voltages12 / 24 / 48 VDC
Weight680 g

Request the right configuration

Include the full model number, voltage, required airflow and pressure, quantity and intended application.

Inquire about JF17151

Price, lead time, wiring and control options are confirmed for the selected configuration.

171mm round high-performance DC fan

JF17151 — Ø171 × 51.5 mm

Aluminum round-frame, dual-ball-bearing high-pressure fan for HVAC, inverters and industrial ventilation. Speed options range from 2,000 to 6,500 RPM.

JF17151 171 mm round DC axial fan
JF17151 aluminum round-frame DC axial fan.

Download JF17151 datasheet (PDF)

Dimensions & performance

JF17151 round fan dimension drawing
JF17151 dimension drawing: Ø171 × 51.5 mm round frame.
JF17151 airflow and static-pressure curves
Airflow and static-pressure curves from 2,000 to 6,500 RPM.

Model parameters & configuration options

JF17151 electrical, airflow, pressure and acoustic values from the supplied data sheet.
ModelRated voltageOperating rangeCurrentPowerSpeedAirflowStatic pressureNoise
JF17151-12L12 VDC8.0–13.5 VDC0.43 A5.16 W2,000 RPM3.88 m³/min / 136.95 CFM6.42 mmH2O / 0.25 inH2O46 dB(A)
JF17151-24L24 VDC18–26.5 VDC0.21 A5.04 W2,000 RPM3.88 m³/min / 136.95 CFM6.42 mmH2O / 0.25 inH2O46 dB(A)
JF17151-48L48 VDC36–54 VDC0.13 A6.24 W2,000 RPM3.88 m³/min / 136.95 CFM6.42 mmH2O / 0.25 inH2O46 dB(A)
JF17151-12LL12 VDC8.0–13.5 VDC0.84 A10.08 W2,500 RPM4.54 m³/min / 160.16 CFM8.38 mmH2O / 0.33 inH2O52 dB(A)
JF17151-24LL24 VDC18–26.5 VDC0.34 A8.16 W2,500 RPM4.54 m³/min / 160.16 CFM8.38 mmH2O / 0.33 inH2O52 dB(A)
JF17151-48LL48 VDC36–54 VDC0.20 A9.60 W2,500 RPM4.54 m³/min / 160.16 CFM8.38 mmH2O / 0.33 inH2O52 dB(A)
JF17151-12M12 VDC8.0–13.5 VDC1.50 A18.00 W3,000 RPM5.23 m³/min / 184.72 CFM10.69 mmH2O / 0.42 inH2O56 dB(A)
JF17151-24M24 VDC18–26.5 VDC0.56 A13.44 W3,000 RPM5.23 m³/min / 184.72 CFM10.69 mmH2O / 0.42 inH2O56 dB(A)
JF17151-48M48 VDC36–54 VDC0.32 A15.36 W3,000 RPM5.23 m³/min / 184.72 CFM10.69 mmH2O / 0.42 inH2O56 dB(A)
JF17151-12MM12 VDC8.0–13.5 VDC2.00 A24.00 W3,500 RPM7.03 m³/min / 248.22 CFM17.84 mmH2O / 0.70 inH2O60 dB(A)
JF17151-24MM24 VDC18–26.5 VDC0.90 A21.60 W3,500 RPM7.03 m³/min / 248.22 CFM17.84 mmH2O / 0.70 inH2O60 dB(A)
JF17151-48MM48 VDC36–54 VDC0.54 A25.92 W3,500 RPM7.03 m³/min / 248.22 CFM17.84 mmH2O / 0.70 inH2O60 dB(A)
JF17151-12H12 VDC8.0–13.5 VDC3.75 A45.00 W4,500 RPM9.41 m³/min / 332.23 CFM31.12 mmH2O / 1.23 inH2O65 dB(A)
JF17151-24H24 VDC18–26.5 VDC1.85 A44.40 W4,500 RPM9.41 m³/min / 332.23 CFM31.12 mmH2O / 1.23 inH2O65 dB(A)
JF17151-48H48 VDC36–54 VDC0.95 A45.60 W4,500 RPM9.41 m³/min / 332.23 CFM31.12 mmH2O / 1.23 inH2O65 dB(A)
JF17151-12HH12 VDC8.0–13.5 VDC5.00 A65.04 W5,000 RPM10.53 m³/min / 371.86 CFM38.17 mmH2O / 1.50 inH2O69 dB(A)
JF17151-24HH24 VDC18–26.5 VDC2.48 A64.80 W5,000 RPM10.53 m³/min / 371.86 CFM38.17 mmH2O / 1.50 inH2O69 dB(A)
JF17151-48HH48 VDC36–54 VDC1.25 A60.00 W5,000 RPM10.53 m³/min / 371.86 CFM38.17 mmH2O / 1.50 inH2O69 dB(A)
JF17151-12U12 VDC8.0–13.5 VDC6.30 A75.60 W5,500 RPM11.67 m³/min / 411.96 CFM45.08 mmH2O / 1.77 inH2O71 dB(A)
JF17151-24U24 VDC18–26.5 VDC3.10 A74.40 W5,500 RPM11.67 m³/min / 411.96 CFM45.08 mmH2O / 1.77 inH2O71 dB(A)
JF17151-48U48 VDC36–54 VDC1.56 A75.00 W5,500 RPM11.67 m³/min / 411.96 CFM45.08 mmH2O / 1.77 inH2O71 dB(A)
JF17151-24UH24 VDC18–26.5 VDC5.32 A127.70 W6,500 RPM13.84 m³/min / 488.75 CFM60.38 mmH2O / 2.38 inH2O82.5 dB(A)
JF17151-48UH48 VDC36–54 VDC2.62 A125.80 W6,500 RPM13.84 m³/min / 488.75 CFM60.38 mmH2O / 2.38 inH2O82.5 dB(A)
Check the full model designation on the data sheet. Verify performance at the system operating point and validate the fan in the finished equipment.

Start with your JF171 cooling requirements.

Share the voltage, airflow, static pressure, operating conditions and quantity.

Request a quote →