Skip to content

DC axial fans

JF092 — 92mm DC cooling fans

Review the JF092 92mm DC axial cooling fan family, source specification sheets and dimensions. Send your required configuration to JyFan.

Model selection

FamilyJF092
Frame / size92 × 92 × 25 mm — JF9225 (Standard range)
92 × 92 × 25 mm — JF9225 (High-speed range)
92 × 92 × 38 mm — JF9238
Power typeDC
Bearing systemSleeve / Hydraumatic / Dual Ball
Life Expectancy30,000 hrs (Sleeve) continuous operating under 25°C, 65% RH; 40,000 hrs (Hydraumatic) continuous operating under 25°C, 65% RH; 50,000 hrs (Dual Ball) continuous operating under 25°C, 65% RH.
Selection documentsSee the dimensions, performance curves and model tables below.

Request the right configuration

Include the full model number, voltage, required airflow and pressure, quantity and intended application.

Inquire about JF092

Price, lead time, bearing and control options are confirmed for the selected configuration.

92mm DC fan series

JF9225 — Standard range

Review the product image, dimension drawing, performance curve and model-specific parameters for this JF9225 series.

JF9225 DC cooling fan
JF9225 DC cooling fan.

Download JF9225 datasheet (PDF)

Dimensions & performance

JF9225 dimension drawing
Dimension drawing
JF9225 airflow and static-pressure curve
Airflow and static-pressure curve

Model parameters & configuration options

JF9225 configuration values transcribed from the supplied product data.
ModelRated voltageOperating rangeCurrentPowerSpeedAirflowStatic pressureNoise
JF9225-12L12 VDC7.0 to 13.5 VDC0.07 A0.84 W2000 RPM0.91 m³/min / 32.29 CFM1.97 mmH2O / 0.08 inH2O26.0 dB(A)
JF9225-24L24 VDC18 to 26.5 VDC0.05 A1.20 W2000 RPM0.91 m³/min / 32.29 CFM1.97 mmH2O / 0.08 inH2O26.0 dB(A)
JF9225-12M12 VDC7.0 to 13.5 VDC0.10 A1.20 W2500 RPM1.17 m³/min / 41.34 CFM3.12 mmH2O / 0.12 inH2O33.2 dB(A)
JF9225-24M24 VDC18 to 26.5 VDC0.06 A1.44 W2500 RPM1.17 m³/min / 41.34 CFM3.12 mmH2O / 0.12 inH2O33.2 dB(A)
JF9225-48M48 VDC36 to 54 VDC0.04 A1.92 W2500 RPM1.17 m³/min / 41.34 CFM3.12 mmH2O / 0.12 inH2O33.2 dB(A)
JF9225-12H12 VDC7.0 to 13.5 VDC0.23 A2.76 W3500 RPM1.65 m³/min / 58.11 CFM5.58 mmH2O / 0.22 inH2O42.6 dB(A)
JF9225-24H24 VDC18 to 26.5 VDC0.13 A3.12 W3500 RPM1.65 m³/min / 58.11 CFM5.58 mmH2O / 0.22 inH2O42.6 dB(A)
JF9225-48H48 VDC36 to 54 VDC0.06 A2.88 W3500 RPM1.65 m³/min / 58.11 CFM5.58 mmH2O / 0.22 inH2O42.6 dB(A)
JF9225-24H24 VDC18 to 26.5 VDC0.20 A4.80 W4500 RPM2.08 m³/min / 73.55 CFM8.57 mmH2O / 0.34 inH2O49.0 dB(A)
JF9225-48H48 VDC36 to 54 VDC0.11 A5.28 W4500 RPM2.08 m³/min / 73.55 CFM8.57 mmH2O / 0.34 inH2O49.0 dB(A)
Configuration marks shown in the supplied option charts. Confirm availability for the selected model and operating voltage.
Function groupMarked option(s)Other options shown in the charts
Motor protectionRP, LPSS, CL, OVP
Signal outputFG, RDRDB, LD
Speed control modePWMTC, VC, CC, CS

92mm DC fan series

JF9225 — High-speed range

Review the product image, dimension drawing, performance curve and model-specific parameters for this JF9225 series.

JF9225 DC cooling fan
JF9225 DC cooling fan.

Download JF9225 High Performance datasheet (PDF)

Dimensions & performance

JF9225 dimension drawing
Dimension drawing
JF9225 airflow and static-pressure curve
Airflow and static-pressure curve

Model parameters & configuration options

JF9225 configuration values transcribed from the supplied product data.
ModelRated voltageOperating rangeCurrentPowerSpeedAirflowStatic pressureNoise
JF9225-12H12 VDC7.0 to 13.5 VDC0.40 A4.80 W4000 RPM2.36 m³/min / 83.41 CFM7.16 mmH2O / 0.28 inH2O49.0 dB(A)
JF9225-24H24 VDC18 to 26.5 VDC0.25 A6.00 W4000 RPM2.36 m³/min / 83.41 CFM7.16 mmH2O / 0.28 inH2O49.0 dB(A)
JF9225-48H48 VDC36 to 54 VDC0.13 A6.24 W4000 RPM2.36 m³/min / 83.41 CFM7.16 mmH2O / 0.28 inH2O49.0 dB(A)
JF9225-12H12 VDC7.0 to 13.5 VDC0.55 A6.60 W4500 RPM2.63 m³/min / 92.99 CFM8.79 mmH2O / 0.35 inH2O53.0 dB(A)
JF9225-24H24 VDC18 to 26.5 VDC0.32 A7.68 W4500 RPM2.63 m³/min / 92.99 CFM8.79 mmH2O / 0.35 inH2O53.0 dB(A)
JF9225-48H48 VDC36 to 54 VDC0.17 A8.16 W4500 RPM2.63 m³/min / 92.99 CFM8.79 mmH2O / 0.35 inH2O53.0 dB(A)
JF9225-12U12 VDC7.0 to 13.5 VDC1.05 A12.60 W5000 RPM2.94 m³/min / 103.80 CFM10.66 mmH2O / 0.42 inH2O56.3 dB(A)
JF9225-24U24 VDC18 to 26.5 VDC0.53 A12.70 W5000 RPM2.94 m³/min / 103.80 CFM10.66 mmH2O / 0.42 inH2O56.3 dB(A)
JF9225-48U48 VDC36 to 54 VDC0.26 A12.48 W5000 RPM2.94 m³/min / 103.80 CFM10.66 mmH2O / 0.42 inH2O56.3 dB(A)
Configuration marks shown in the supplied option charts. Confirm availability for the selected model and operating voltage.
Function groupMarked option(s)Other options shown in the charts
Motor protectionRP, LPSS, CL, OVP
Signal outputFG, RDRDB, LD
Speed control modePWMTC, VC, CC, CS

92mm DC fan series

JF9238 — High-performance DC axial fan

The JF9238 is a 92 × 92 × 38 mm DC axial fan series for applications requiring higher pressure and airflow than the 25 mm-thick range. Select the voltage, speed grade and control options for the operating point.

JF9238 92 mm DC cooling fan
JF9238 92 mm DC cooling fan.

Download JF9238 datasheet (PDF)

Dimensions & series data

JF9238 92 by 92 by 38 mm dimension drawing
JF9238 dimension drawing: 92 × 92 × 38 mm.
JF9238 series information transcribed from the supplied data sheet.
Frame size92 × 92 × 38 mm
Rated voltage options12 VDC, 24 VDC, 48 VDC
Bearing systemDual ball bearing
Speed grades3,000 to 9,000 RPM, model dependent
Performance selectionAirflow, static pressure, current, power and noise vary by voltage and speed grade. Use the model rows in the original data sheet for final selection.
Available functionsMotor protection and signal/control options available by configuration.

Model parameters & configuration options

JF9238 ordering framework. Confirm the final electrical and acoustic values from the linked data sheet before release.
Model familyVoltageSpeed rangeFrameBearingSelection guidance
JF923812 / 24 / 48 VDC3,000–9,000 RPM92 × 92 × 38 mmDual ballSpecify the voltage, required airflow/static pressure, control functions, wire and connector requirements.
Check the full model designation on each document. Verify performance at your system operating point and validate the fan in the finished equipment.

Start with your cooling requirements.

Share the size, voltage, airflow, operating conditions and quantity.

Request a quote →